INTRADISCAL PRESSURE CHANGES DURING MANUAL CERVICAL DISTRACTION: A CADAVERIC STUDY
 
   

Intradiscal Pressure Changes During
Manual Cervical Distraction:
A Cadaveric Study

This section was compiled by Frank M. Painter, D.C.
Send all comments or additions to:
  Frankp@chiro.org
 
   

FROM:   Evid Based Complement Alt Med. 2013 (Aug 20); 2013: 954134 ~ FULL TEXT

  OPEN ACCESS   


M. R. Gudavalli, T. Potluri, G. Carandang, R. M. Havey, L. I. Voronov,
J. M. Cox, R. M. Rowell, R. A. Kruse, G. C. Joachim, A. G. Patwardhan,
C. N. R. Henderson, and C. Goertz

Palmer Center for Chiropractic Research,
741 Brady Street, Davenport, IA 52803, USA.


The objective of this study was to measure intradiscal pressure (IDP) changes in the lower cervical spine during a manual cervical distraction (MCD) procedure. Incisions were made anteriorly, and pressure transducers were inserted into each nucleus at lower cervical discs. Four skilled doctors of chiropractic (DCs) performed MCD procedure on nine specimens in prone position with contacts at C5 or at C6 vertebrae with the headpiece in different positions. IDP changes, traction forces, and manually applied posterior-to-anterior forces were analyzed using descriptive statistics. IDP decreases were observed during MCD procedure at all lower cervical levels C4-C5, C5-C6, and C6-C7. The mean IDP decreases were as high as 168.7 KPa. Mean traction forces were as high as 119.2 N. Posterior-to-anterior forces applied during manual traction were as high as 82.6 N. Intraclinician reliability for IDP decrease was high for all four DCs. While two DCs had high intraclinician reliability for applied traction force, the other two DCs demonstrated only moderate reliability. IDP decreases were greatest during moving flexion and traction. They were progressevely less pronouced with neutral traction, fixed flexion and traction, and generalized traction.



The Full-Text Article:

1.   Introduction

Neck pain and neck-related shoulder and arm pain are a major health problem in Western societies [1–5] . Symptoms may include pain, tingling, numbness, stiffness, loss of coordination or physical strength, skin discoloration, and temperature differences located in the neck, shoulder, arm, elbow, wrist, hand, and/or fingers. These complaints cause discomfort and may lead to severe long-term pain and physical disability creating an economic burden due to work absences and healthcare costs [1] . In 2003 the 12-month prevalence of neck and shoulder pain in The Netherlands was estimated at 31.4% and 30.3%, respectively [6] . In 2008, approximately 6% of US adults reported an ambulatory visit for a primary diagnosis of a back or neck condition (13.6 million). Between 1999 and 2008, the mean inflation-adjusted annual expenditures on medical care for these patients increased by 95% (from $487 to $950); most of the increase was accounted for by increased costs for medical specialists, as opposed to primary care physicians. During the study period, the mean inflation-adjusted annual expenditures on chiropractic care were relatively stable. Physical therapy was the most costly service overall [7] .

Spinal manipulation is used by doctors of chiropractic (DC), osteopathic physicians, and physical therapists to treat musculoskeletal disorders [8–12] . While spinal manipulation has been shown to be effective in some studies [13] , and researchers have performed experimental studies with humans and animals [14–21] , the exact mechanisms behind these techniques are not fully understood [22] .

A form of chiropractic manipulation performed using a specially designed table that incorporates traction called manual cervical distraction (MCD), or flexion distraction, was developed by Cox [23] . Several case studies have reported clinical improvement of patients with neck pain [24–28] . MCD is hypothesized to create intersegmental motion at a targeted segment under the application of traction via a load localizing hand contact utilizing a treatment table [23] . The effects of traction for the cervical spine may include separation of vertebrae, reduction of intradiscal pressure (IDP), facet joint separation, increase of intervertebral foramen, and soft tissue stretching [29–31] .

The resulting traction-induced intersegmental motion is thought to open the intervertebral foramen and decrease intradiscal pressures (IDPs).

Li et al. [32] and Wu et al. [33] used a materials testing system to simulate cervical high velocity low amplitude spinal manipulation (HVLA SM) on human cervical cadaveric specimens. They reported IDP decreases during the traction phase prior to delivering HVLA and IDP increases during the rotational thrust manipulation. However, the clinical application of these findings is unclear because both Li and Wu performed their simulations with material testing systems; substantially different procedures than those used by clinicians. By contrast, the MCD procedure used in the present study is widely used. Sixty-four percent of doctors of chiropractic (DCs) treat neck pain with this method [34] .

The objectives of this study were; in unembalmed cadavers with intact head, neck, and trunk: (1) measure IDP in the lower cervical spine (C4-C5, C5-C6, C6-C7, and C7-T1) and (2) during the MCD procedure performed by study DCs, measure the magnituded and reliability of applied forces.



2.   Materials and Methods

Figure 1

A specially modified treatment table incorporated a multicomponent (3 forces and 3 moments) force plate (Model number 2850-06, Bertec, Inc., Columbus, OH) into the thorax section of the table to which the specimen torso was mounted (Figure 1). The head support of the table allowed linear motion to create traction of the specimen's cervical spine, flexion motion of the head, and locking of the head support at a given flexion angle.

      2.1.   Specimens

Figure 2

Table 1

Nine fresh-frozen cadavers with intact head, neck, and trunk with shoulders were procured from approved tissue banks and stored in freezers at -20°C. Radiographs were taken to exclude severe degeneration, trauma, tumor, or significant osteoporosis. Figure 2 is a static video fluoroscopic image showing (see arrows) the location of pressure transducers in the nucleus of the C4-C5, C5-C6, C6-C7, and C7-T1 intervertebral discs. Intervertebral discs were graded from the static video fluoroscopic images by three independent observers using disc height measurements [35, 36] . Demographics of the specimens are provided in Table 1.

Pressure sensors (Model 060, Precision Measurement, Inc., Ann Arbor, MI) were calibrated using a hand-held pressure calibration device (Model number HTP1, Druck, Ltd., Leicester, UK). Pressure calibrations were linear, and a first-order polynomial function was used to describe each calibration. Specimens were thawed at room temperature. Pressure transducers were inserted through anterior approach into the nucleus pulposus of C4-C5, C5-C6, C6-C7, and C7-T1. The transducers were inserted through a 14-gauge cannula into each disc nucleus under video fluoroscopy guidance (OEC-9800, GE Healthcare Systems, Waukesha, WI).

After the sensors were inserted, the cadaver was placed in a prone position with the head resting on the moveable head support and the thorax resting on the fixed section of the table, which was mounted on the force plate. The thorax was rigidly secured to the table section and underlying force plate by Velcro straps. The head and upper cervical spine were positioned on the moveable headpiece. The thorax was positioned on the middle section of the table with the cervical spine between the cervical headpiece and thoracic section of the table. This allowed manual contact of the cervical and upper thoracic spine vertebrae for distraction in neutral position or in a flexion posture of the head.

MCD was performed on the cadaver spines by three field clinicians and one academic/research clinician. All four clinicians are considered experts in delivering MCD.

Figure 3

Figure 4

The MCD treatment protocol used was as follows. The web of the hand between thumb and index finger was placed on the spinous process and lamina above the segment to be distracted (Figure 3(a)). A controlled cephalad distraction was therefore applied to the vertebral segment by combined hand contact and headpiece motion of the table in the longitudinal direction of the spine. The distraction along the length of the spine was applied in three twenty-second-distraction sessions. During each twenty-second session there were five loading-unloading distraction cycles (Figure 4). These distraction sessions were applied at the C5 and C6 hand contact locations.

The cervical headpiece of the table was then placed in a fixed flexion angle of 15 degrees, and the MCD procedure was repeated while the cervical head piece of the table moved in flexion and slid longitudinally. The cervical headpiece of the table was allowed to move in flexion freely while at the same time sliding on the cranial caudal axis to create traction. Thus the clinician was moving the head piece in flexion and traction simultaneously, and the cervical spine was subjected to flexion and traction movements simultaneously.

In another procedure, occipital restraints were placed on the cadaver skull and the doctor's hand contacted the vertebral arch at the T1 level with the thenar eminence of the hand contacting the spinous process at T1 level (Figure 3(b)). A generalized traction was then applied to the entire cervical spine by moving the table's tiller bar in the cephalad (superior) direction. This procedure was repeated with 15 degrees of flexion of the headpiece.

Custom data collection software was developed using a TestPoint programming environment (TestPoint v7, Measurement Computing, Inc., Norton, MA). The software allowed data collection from the pressure transducers and force plate simultaneously. Data were collected through an analog to digital convertor (Model NI-6225, National Instruments, Inc., Austin TX) at a sampling rate of 150 Hz. When data collection was complete, it was displayed in graphical form and imported into MS Excel.

      2.2.   Data Processing/Reduction

Custom written macros in MS Excel identified the beginning and the peak force application for the 3 sets of 5 force application cycles. The IDPs were recorded at the beginning of the force application and at the peak of force application for all five cycles in each set. The mean of the 15 cycles was calculated.

      2.3.   Statistical Analysis

Descriptive statistics (Systat v10.2, Systat Software, Inc., Chicago, IL) in terms of mean and standard deviation were computed for the changes in IDP and the forces of all measured data. Intraclass correlation coefficients (ICCs) were calculated for each clinician to evaluate intraclinician reliability across the three repititions of applied force.



3.   Results

Table 2

Figure 5

Table 3

Table 4

Study Chiropractor 1 (DC1) performed MCD on eight out of nine specimens, DCs 2 and 4 performed MCD on four out of nine specimens, and DC3 performed MCD on three out of nine specimens. IDP data could not be obtained on one of the nine specimens (DCs 1, 3, and 4 performed on this specimen) due to equipment technical difficulties. Thus IDP data and the force data had a different number of observations. Intervertebral discs were graded from the static video fluoroscopic images by three independent observers. Based on the disc height classification, most of the discs (34 out of 36) were of Grade I, one of Grade II, and one of Grade III degeneration (Table 2).

Figure 4 shows typical IDP graphs at each of the lower cervical discs (C4-C5, C5-C6, C6-C7, and C7-T1) as a function of the duration of treatment, demonstrating the decrease in IDP as the DC applied MCD during the five loading/unloading cycles in a given session. Figure 5 presents a typical graph showing the changes in IDP as a function of traction force (as measured by the force plate under the thorax support).

Table 2 gives the mean and SD of IDP changes under different traction conditions for all four DCs. Varying magnitudes of IDP decreases were observed across the different DCs, contact location, and traction procedure in different positions of the head piece. Table 3 gives the mean and SD of the applied forces for the four DCs under different traction conditions. Table 4 provides intraclass correlation coefficients for assessing IDP and traction force intraclinician reliability during the three repetitions of MCD.



4.   Discussion

Decreased IDP is thought to allow retraction of the prolapsed disc, contributing to improved solute and nutrient transport, and altering the chemical environment of nociceptors in the outer annular layers of the disc [29] . Manually localized lumbar distraction has already been shown to decrease IDP in cadaveric lumbar discs [29] . In addition, its clinical effectiveness for patients with radiculopathy has been demonstrated in a randomized clinical trial [37] . According to practicing clinicians (personal communications) MCD procedure is commonly used to treat neck pain patients with radiating symptoms to the arms where discs in the lower cervical spine (C4-C5, C5-C6, C6-C7, and C7-T1) are involved.

This study was designed to measure IDP changes during a manual cervical distraction procedure in the lower cervical discs (C4-C5, C5-C6, C6-C7, and C7-T1). MCD is commonly performed in a prone position and is different from other traction procedures used in various studies [38–46] . In this study, longitudinal traction along the length of the spine with contacts at C5 and C6 was performed with the cadaver in the prone position. This position allowed contacting the posterior arch of the specified cervical vertebra (C5 or C6). This is substantially different than the standard supine, upright seated, or standing forms of spine traction that apply forces to the vertebral column with no localizing contact.

Although the studied procedures may all be applied to patients in the clinical setting, most patients receive one, but not all, of these procedures. The majority of discogenic pain patients receive neutral traction or fixed flexion and traction. Few DCs use combined moving flexion and MCD. Patient tolerance guides selection of the specific traction procedure. Part of the study was to determine if there was additional or varied physiological benefit (drop in intradiscal pressure) when performing the traction alone or traction with fixed flexion or combining the flexion and traction simultaneously. Recovery time of two minutes was allowed between the different traction conditions. Previous biomechanical studies have used recovery times ranging from 15 seconds to 4 minutes [47–52] . To minimize testing time and tissue degradation we chose a recovery time of two minutes.

IDP decreases were observed at all levels for DC 1 under neutral traction conditions. IDP increased at C7-T1 level for some of the DCs when the contact was at C6 level. During generalized traction, IDP at C7-T1 increased for most of the DCs. In general, DCs applied higher forces when contacting at C5 compared to C6 and higher forces during moving flexion compared to neutral and fixed flexion tractions (Table 3). DC4 applied the maximum traction force, while DC3 applied the least traction force. DC3 was the clinician in an academic research setting. All four DCs applied posterior-to-anterior (PA) force along with traction. The level of PA forces was higher for DC4, followed by DC1, and then DC2. DC3 had the smallest forces among all the DCs. All the DCs applied higher PA force when contact was at C6. Contact at C6 was more difficult due to the anatomical region, which may explain this finding.

Traction forces used by the four DCs in our study (Table 3) were in the range reported by several other investigators using home traction application in clinical studies. Raney et al. [53] used traction forces of 23.2lbs (103 N), Young et al. [46] used 35lbs (156 N), Fater and Kernozek [38] used 13.6 Kg (133 N), Tsai et al. [54] used 10%–30% of body weight (47 N–141 N), and Forbush et al. [45] used traction forces of 9–13 kg (88 N–128 N). Young et al. used 5lbs (22 N) as a sham traction force for their control group [46] .

All DCs had high intraclinician reliability on changes in IDP for the three sets of the procedure at all levels (Table 4). This suggests that MCD can be delivered consistently by practicing DCs as well as academic/research clinicians. The traction forces for two of the four DCs had high reliability, while the other two had moderate reliability. This suggests that some DCs may need training to deliver traction forces more consistently. We did not perform interclinician reliability because of the small sample for three of the DCs.

The hand contact position and force for each of the clinicians were likely different and may have influenced the lordosis of the cervical spine which, in turn, may have contributed to variations in the tractions forces. This could be one reason why the intraclass coefficients are smaller for two of the four DCs. The PA forces for these two DCs were higher. The decrease in intradiscal pressure can be induced by not only the applied traction forces but also the tensile forces in the intervertebral disc produced by increased lordosis. Thus, while the introduction of a lordosis may have decreased the reliability of the traction force delivered by a DC, the additive effect on the intradiscal pressure due to traction and lordosis may have improved the reliability of the intradiscal pressure change.

Wu et al. [33] reported IDP changes during simulated spinal manipulations on 7 cadaveric cervical spine specimens [33] . They tested the cadavers in an upright position using an MTS machine with compressive load (100 N), traction load (200 N), flexion, and extension (10 deg., 20 deg.). During traction phase they reported mean pressure decreases of 75 KPa at C3-C4, 84 KPa at C4-C5, and 70 KPa at C5-C6. Li et al. [32] reported significant decreases in IDP during simulated traction loads of 150–200 N on a cervical spine in an upright (vertical) position. They also observed increases in IDP during rotation and concluded that traction followed by rotation is a safer manipulation.

Our studies are based on prone traction as applied during clinical practice whereas the studies by Yi-Kai et al. and Wu et al. were based on vertical position simulated using a material testing system. The IDP decreases at C4-C5 and C5-C6 under manual cervical distraction in our study were comparable to the reported values by Wu et al. during the traction phase. The mean IDP decreases reported by Li et al. [32] at 200 N were much higher than observed in our study and those of the study by Wu et al. [33] . It is important to note that we did not measure pressure changes at C3-C4 and Yi-Kai et al. and Wu et al. did not report pressure changes at C6-C7 and C7-T1. In addition, the forces the forces used by our clinicians were smaller than the simulated forces used by Wu et al. [33] and Li et al. [32] . Traction forces of 200 N are much higher than the forces commonly used in clinical studies as well as our study.

Li et al. [32] and Wu et al. [33] obtained cadaveric specimens from the Chinese population while our specimens were drawn from the US population. In addition, Li et al. [32] specimens were male, 23–34 years old, and Wu et al. [33] specimens were male and female, 28–39 years of age. Cadaveric specimens in our study were male and female, 28-54 years of age. This could contribute to some differences in the observations. This could contribute to some of the differences in the results of our study compared to Li et al. [32] and Wu et al. [33] .

Disc degeneration has an influence on changes in IDP. In our study, only two discs were found to have greater than Grade I degeneration. Hence we did not account for disc degeneration as a factor in our observations.

      4.1.   Limitations

Unembalmed cadavers were used in this study and it is appreciated that active musculature during in vivo situations could alter the changes in the IDP. It is a standard practice in numerous biomechanical studies published in the literature to use human cadaveric spine specimens to assess the mechanical response of intervertebral discs in order to understand how the human spine may respond to physiologic loads (forces and moments) experienced during activities of daily living. Three of the four DCs in our study are in clinical practice and use this technique on a day-to-day basis, but they were not given instructions regarding control of maximum force application. Intervertebral discs were graded based on a single-lateral static view of video fluoroscopic images, which is not optimal. For future studies we will consider magnetic resonance images of the spine to grade the discs. We do not know of any better technology that can be used at this stage.



5.   Conclusions

In this cadaveric study we observed decreases in IDP in the lower cervical spine during a chiropractic MCD procedure in prone position. Based on the maximum number of specimens DC1 has done, moving flexion and traction seem to reduce more IDP, followed by neutral traction, fixed flexion and tractions, and generalized traction. Although the doctors of chiropractic in this study demonstrated good intraclinician reliability, the magnitude of traction forces varied. Larger powered studies should be undertaken to determine if these decreases in IDP are significant depending on the doctor, contact location, and the different traction procedures. Also, the clinical significance of these differences is unknown.


Conflict of Interests

James Cox is the developer of the MCD procedure used in this study. He teaches this technique and is also a consultant to the manufacturer of the traction table modified in the study (Haven Innovations, Inc., Michigan, USA). Kruse and Joachim are in private practice and also assist Cox in teaching this MCD technique. There are no conflict of interests with the other companies listed in this study: Bertec, Inc., (Columbus, OH); Druck Ltd., (Leicester, UK); GE Healthcare Systems (Waukesha, WI); TestPoint Measurement Computing, Inc., (Norton, MA); National Instruments, Inc., (Austin TX); Systat Software, Inc., (Chicago, IL).


Acknowledgments

This investigation was supported by Grant number 1 U19 AT004663-01 from the National Center for Complementary and Alternative Medicine and conducted in a facility constructed with support from Research Facilities Improvement Program Grant no. C06 RR15443-01 from the National Center for Research Resources, National Institutes of Health. Lastly, the authors acknowledge the monetary donations of several chiropractic clinicians to support this research.



References:

  1. Picavet HSJ, Hazes JMW.
    Prevalence of self reported musculoskeletal diseases is high.
    Annals of the Rheumatic Diseases. 2003;62(7):644–650

  2. Urwin M, Symmons D, Allison T, et al.
    Estimating the burden of musculoskeletal disorders in the community:
    the comparative prevalence of symptoms at different anatomical sites, and
    the relation to social deprivation.
    Annals of the Rheumatic Diseases. 1998;57(11):649–655

  3. Cote P, van der Velde G, Cassidy JD, Carroll LJ, Hogg-Johnson S, Holm LW, et al.
    The Burden and Determinants of Neck Pain in Workers: Results of the Bone and Joint Decade
    2000–2010 Task Force on Neck Pain and Its Associated Disorders

    Spine (Phila Pa 1976). 2008 (Feb 15); 33 (4 Suppl): S60-74

  4. Holm LW, Carroll LJ, Cassidy JD, et al.
    The Burden and Determinants of Neck Pain in Whiplash-associated Disorders after Traffic Collisions:
    Results of the Bone and Joint Decade 2000–2010 Task Force on Neck Pain and Its Associated Disorders

    Spine (Phila Pa 1976). 2008 (Feb 15); 33 (4 Suppl): S52-59

  5. Hogg-Johnson, S, van der Velde, G, Carroll, LJ et al.
    The Burden and Determinants of Neck Pain in the General Population: Results of the
    Bone and Joint Decade 2000–2010 Task Force on Neck Pain and Its Associated Disorders

    Spine (Phila Pa 1976). 2008 (Feb 15); 33 (4 Suppl): S39–51

  6. Picavet HSJ, Schouten JSAG.
    Musculoskeletal pain in the Netherlands: prevalences, consequences and risk groups,
    the DMC3-study.
    Pain. 2003;102(1-2):167–178

  7. Davis MA, Onega T, Weeks WB, Lurie JD.
    Where the United States Spends its Spine Dollars: Expenditures on Different Ambulatory Services
    for the Management of Back and Neck Conditions

    Spine (Phila Pa 1976). 2012 (Sep 1); 37 (19): 1693–1701

  8. Downie AS, Vemulpad S, Bull PW:
    Quantifying the High-velocity, Low-amplitude Spinal Manipulative Thrust: A Systematic Review
    J Manipulative Physiol Ther. 2010 (Sep); 33 (7): 542-53

  9. Rubinstein SM, Leboeuf-Yde C, Knol DL, de Koekkoek TE,
    Pfeifle CE, van Tulder MW.
    The Benefits Outweigh the Risks for Patients Undergoing Chiropractic
    Care for Neck Pain A Prospective, Multicenter, Cohort Study

    J Manipulative Physiol Ther 2007 (Jul); 30 (6): 408–418

  10. Cagnie B, Vinck E, Beernaert A, et al.
    How Common Are Side Effects of Spinal Manipulation
    And Can These Side Effects Be Predicted?

    Manual Therapy 2004 (Aug); 9 (3): 151–156

  11. Bicalho E, Palma Setti JA, Macagnan J, Rivas Cano JL, Manffra EF.
    Immediate effects of a high-velocity spine manipulation in paraspinal muscles
    activity of nonspecific chronic low-back pain subjects.
    Manual Therapy. 2010;15(5):469–475

  12. Vernon HT, Triano JJ, Ross JK, Tran SK, Soave DM, Dinulos MD.
    Validation of a Novel Sham Cervical Manipulation Procedure
    Spine J. 2012 (Nov); 12 (11): 1021–1028

  13. Vincent K, Maigne JY, Fischhoff C, Lanlo O, Dagenais S.
    Systematic review of manual therapies for nonspecific neck pain.
    Joint Bone Spine. 2012

  14. Colloca, C. J., Gunzburg, R., Freeman, B. J.,
    Szpalski, M., Afi fi , M., & Moore, R. J.
    Biomechancial Quantification of Pathologic Manipulable Spinal Lesions:
    An In Vivo Ovine Model of Spondylolysis and Intervertebral Disc Degeneration

    J Manipulative Physiol Ther 2012 (Jun); 35 (5): 354–366

  15. Millan M, Leboeuf-Yde C, Budgell B, Descarreaux M, Amorim MA.
    The effect of spinal manipulative therapy on spinal range of motion:
    a systematic literature review.
    Chiropractic & Manual Therapies. 2012;20:p. 23

  16. Millan M, Leboeuf-Yde C, Budgell B, Amorim MA.
    The Effect of Spinal Manipulative Therapy on Experimentally Induced Pain:
    A Systematic Literature Review

    Chiropractic & Manual Therapies 2012 (Aug 10); 20 (1): 26

  17. Martνnez-Segura R, Fernαndez-de-las Peρas C, Ruiz-Sαez M, Lσpez-Jimιnez C:
    Immediate Effects on Neck Pain and Active Range of Motion After a Single Cervical
    High-velocity Low-amplitude Manipulation in Subjects Presenting with Mechanical
    Neck Pain: A Randomized Controlled Trial

    J Manipulative Physiol Ther 2006 (Sep); 29 (7): 511–517

  18. Martinez-Segura R, De-la-Llave-Rincon AI,
    Ortega-Santiago R, Cleland JA, Fernandez-de-Las-Penas C.
    Immediate changes in widespread pressure pain sensitivity, neck pain, and
    cervical range of motion after cervical or thoracic thrust manipulation in
    patients with bilateral chronic mechanical neck pain: a randomized clinical trial.
    Journal of Orthopaedic & Sports Physical Therapy. 2012;42:806–814

  19. Salem W, Klein P.
    In vivo 3D kinematics of the cervical spine segments during pre-manipulative
    positioning at the C4/C5 level.
    Man Ther. 2013;18(4):321–326

  20. Masaracchio M, Cleland JA, Hellman M, Hagins M.
    Short-term combined effects of thoracic spine thrust manipulation and cervical spine
    non-thrust manipulation in individuals with mechanical neck pain: a randomized clinical trial.
    Journal of Orthopaedic & Sports Physical Therapy. 2012;43(3):118–127

  21. Cross KM, Kuenze C, Grindstaff T, Hertel J.
    Thoracic spine thrust manipulation improves pain, range of motion, and
    self-reported function in patients with mechanical neck pain: a systematic review.
    Journal of Orthopaedic and Sports Physical Therapy. 2011;41(9):633–643

  22. Cramer G, Budgell B, Henderson C, Khalsa P, Pickar J.
    Basic Science Research Related to Chiropractic Spinal Adjusting:
    The State of the Art and Recommendations Revisited

    J Manipulative Physiol Ther. 2006 (Nov); 29 (9): 726–761

  23. Cox JM.
    Neck, Shoulder, Arm Pain: Mechanism, Diagnosis, Treatment.
    3rd edition 2004

  24. Gudavalli S, Kruse RA.
    Foraminal stenosis with radiculopathy from a cervical disc herniation in a
    33-year-old man treated with flexion distraction decompression manipulation.
    Journal of Manipulative and Physiological Therapeutics. 2008;31(5):376–380

  25. Kruse RA, Cambron JA.
    Large C4/5 spondylotic disc bulge resulting in spinal stenosis and myelomalacia
    in a klippel-feil patient.
    Journal of Alternative and Complementary Medicine. 2012;18(1):96–99

  26. Kruse RA, Imbarlina F, De Bono VF.
    Treatment of cervical radiculopathy with flexion distraction.
    Journal of Manipulative and Physiological Therapeutics. 2001;24(3):206–209

  27. Dougherty P, Bajwa S, Burke J, Dishman JD.
    Spinal manipulation postepidural injection for lumbar and cervical radiculopathy:
    a retrospective case series.
    Journal of Manipulative and Physiological Therapeutics. 2004;27(7):449–456

  28. Cox JM, Aspegren DD.
    Degenerative spondylolisthesis of C7 and L4 in same patient.
    Journal of Manipulative and Physiological Therapeutics. 1988;11(3):195–205

  29. Cox J.
    Low Back Pain: Mechanism, Diagnosis and Treatment.
    Baltimore, Md, USA: Williams & Wilkins; 2011

  30. Michlovitz SL, Harris BA, Watkins MP.
    Therapy interventions for improving joint range of motion: a systematic review.
    Journal of Hand Therapy. 2004;17(2):118–131

  31. Graham N, Gross AR, Goldsmith C, et al.
    Mechanical traction for mechanical neck disorders: a systematic review.
    Journal of Rehabilitation Medicine. 2006;38(3):145–152

  32. Li YK, Zhu QA, Zhong SZ.
    The effect of cervical traction combined with rotatory manipulation on
    cervical nucleus pulposus pressures.
    Journal of Manipulative and Physiological Therapeutics. 1998;21:97–100

  33. Wu LP, Huang YQ, Zhou WH, et al.
    Influence of cervical spine position, turning time, and cervical segment
    on cadaver intradiscal pressure during cervical spinal manipulative therapy.
    Journal of Manipulative and Physiological Therapeutics. 2012;35:428–436

  34. Christensen MG, Mark G, Kollash MW, Hyland JK.
    Practice Analysis of Chiropractic 2010
    National Board of Chiropractic Examiners; 2010.

  35. Pfirrmann CWA, Metzdorf A, Zanetti M, Hodler J, Boos N.
    Magnetic resonance classification of lumbar intervertebral disc degeneration.
    Spine. 2001;26(17):1873–1878

  36. Walraevens J, Liu B, Meersschaert J, et al.
    Qualitative and quantitative assessment of degeneration of cervical
    intervertebral discs and facet joints.
    European Spine Journal. 2009;18:358–369

  37. Gudavalli MR, Cambron JA, McGregor M, et al.
    A randomized clinical trial and subgroup analysis to compare flexion-distraction
    with active exercise for chronic low back pain.
    European Spine Journal. 2006;15(7):1070–1082

  38. Fater DCW, Kernozek TW.
    Comparison of cervical vertebral separation in the supine and seated
    positions using home traction units.
    Physiotherapy Theory and Practice. 2008;24(6):430–436

  39. Wong AMK, Leong CPL, Chen C-M.
    The traction angle and cervical intervertebral separation.
    Spine. 1992;17(2):136–138

  40. Chung C-T, Tsai S-W, Chen C-J, et al.
    Comparison of the intervertebral disc spaces between axial and anterior
    lean cervical traction.
    European Spine Journal. 2009;18(11):1669–1676

  41. Deets D, Hands KL, Hopp SS.
    Cervical traction. A comparison of sitting and supine positions.
    Physical Therapy. 1977;57(3):255–261

  42. Liu J, Ebraheim NA, Sanford CG, Jr., et al.
    Quantitative changes in the cervical neural foramen resulting from axial traction:
    in vivo imaging study.
    Spine Journal. 2008;8(4):619–623

  43. Swezey RL, Swezey AM, Warner K.
    Efficacy of home cervical traction therapy.
    American Journal of Physical Medicine and Rehabilitation. 1999;78(1):30–32

  44. Waylonis GW, Tootle D, Denhart C.
    Home cervical traction: evaluation of alternate equipment.
    Archives of Physical Medicine and Rehabilitation. 1982;63(8):388–391

  45. Forbush SW, Cox T, Wilson E.
    Treatment of patients with degenerative cervical radiculopathy using
    a multimodal conservative approach in a geriatric population: a case series.
    Journal of Orthopaedic and Sports Physical Therapy. 2011;41(10):723–733

  46. Young IA, Michener LA, Cleland JA, Aguilera AJ, Snyder AR.
    Manual therapy, exercise, and traction for patients with cervical radiculopathy:
    a randomized clinical trial.
    Physical Therapy. 2009;89(7):632–642

  47. Panjabi MM, Brand RA, Jr., White AA.,
    III Mechanical properties of the human thoracic spine.
    As shown by three dimensional load displacement curves.
    Journal of Bone and Joint Surgery A. 1976;58(5):642–652

  48. Panjabi MM, Brand RA, Jr., White AA.,
    III Three dimensional flexibility and stiffness properties of the human thoracic spine.
    Journal of Biomechanics. 1976;9(4):185–192

  49. Panjabi MM, White AA, III, Johnson RM.
    Cervical spine mechanics as a function of transection of components.
    Journal of Biomechanics. 1975;8(5):327–336

  50. Panjabi MM, White AA, III, Keller D.
    Stability of the cervical spine under tension.
    Journal of Biomechanics. 1978;11(4):189–197

  51. Schultz AB, Warwick DN, Berkson MH, Nachemson AL.
    Mechanical properties of human lumbar spine motion segments-Part 1: responses in flexion, extension, lateral bending, and torsion.
    Journal of Biomechanical Engineering. 1979;101(1):46–52

  52. Edwards WT, Hayes WC, Posner I, White AA, III, Mann RW.
    Variation of lumbar spine stiffness with load.
    Journal of Biomechanical Engineering. 1987;109(1):35–42

  53. Raney NH, Petersen EJ, Smith TA, et al.
    Development of a clinical prediction rule to identify patients with neck pain likely to benefit from cervical traction and exercise.
    European Spine Journal. 2009;18(3):382–391

  54. Tsai C-T, Chang W-D, Kao M-J, Wang C-J, Lai PT.
    Changes in blood pressure and related autonomic function during cervical traction in healthy women.
    Orthopedics. 2011;34(7):e295–e301

Return to DISC HERNIATION

Since 3-03-2016

                  © 1995–2024 ~ The Chiropractic Resource Organization ~ All Rights Reserved