KINEMATICS OF THE HEAD AND ASSOCIATED VERTEBRAL ARTERY LENGTH CHANGES DURING HIGH-VELOCITY, LOW-AMPLITUDE CERVICAL SPINE MANIPULATION
 
   

Kinematics of the Head and Associated Vertebral Artery
Length Changes During High-velocity, Low-amplitude
Cervical Spine Manipulation

This section was compiled by Frank M. Painter, D.C.
Send all comments or additions to:
  Frankp@chiro.org
 
   

FROM:   Chiropractic & Manual Therapies 2022 (Jun 1); 30 (1): 28 ~ FULL TEXT

  OPEN ACCESS   


Lindsay M. Gorrell, Gregor Kuntze, Janet L. Ronsky, Ryan Carter, Bruce Symons, John J. Triano & Walter Herzog

Human Performance Laboratory,
Faculty of Kinesiology,
University of Calgary,
Calgary, Canada.



Background:   Cervical spine manipulation (CSM) is a frequently used treatment for neck pain. Despite its demonstrated efficacy, concerns regarding the potential of stretch damage to vertebral arteries (VA) during CSM remain. The purpose of this study was to quantify the angular displacements of the head relative to the sternum and the associated VA length changes during the thrust phase of CSM.

Methods:   Rotation and lateral flexion CSM procedures were delivered bilaterally from C1 to C7 to three male cadaveric donors (Jan 2016–Dec 2019). For each CSM the force-time profile was recorded using a thin, flexible pressure pad (100–200 Hz), to determine the timing of the thrust. Three dimensional displacements of the head relative to the sternum were recorded using an eight-camera motion analysis system (120–240 Hz) and angular displacements of the head relative to the sternum were computed in Matlab. Positive kinematic values indicate flexion, left lateral flexion, and left rotation. Ipsilateral refers to the same side as the clinician's contact and contralateral, the opposite. Length changes of the VA were recorded using eight piezoelectric ultrasound crystals (260–557 Hz), inserted along the entire vessel. VA length changes were calculated as D = (L1 – L0)/L0, where L0 = length of the whole VA (sum of segmental lengths) or the V3 segment at CSM thrust onset; L1 = whole VA or V3 length at peak force during the CSM thrust.

Results:   Irrespective of the type of CSM, the side or level of CSM application, angular displacements of the head and associated VA length changes during the thrust phase of CSM were small. VA length changes during the thrust phase were largest with ipsilateral rotation CSM (producing contralateral head rotation): [mean ± SD (range)] whole artery [1.3 ± 1.0 (– 0.4 to 3.3%)]; and V3 segment [2.6 ± 3.6 (– 0.4 to 11.6%)].

Conclusions:   Mean head angular displacements and VA length changes were small during CSM thrusts. Of the four different CSM measured, mean VA length changes were largest during rotation procedures. This suggests that if clinicians wish to limit VA length changes during the thrust phase of CSM, consideration should be given to the type of CSM used.

Keywords:   Cervical spine; Kinematics; Spinal manipulation; Spontaneous vertebral artery dissection; Strain.



From the FULL TEXT Article:

Introduction

Figure 1

Neck pain is a common cause of musculoskeletal pain in the adult population, with annual global prevalence estimates in the range of 17–75% and costs in excess of US$ 8 billion/year in the United States alone [1–3]. Cervical spine manipulation (CSM) is a frequently used treatment modality for patients with neck pain [4, 5] and is recommended in many clinical practice guidelines. [6–8] Despite its demonstrated efficacy [9, 10], concerns remain surrounding the safety of CSM. [11–14] It has been suggested that head and neck extension and rotation during some CSM may stretch and damage the vertebral artery (VA) wall, leading to arterial dissection and stroke. [12, 15, 16] Such damage predominantly occurs in the V3 segment of the artery, which may be vulnerable with elongation (Figure 1), highlighting the importance of investigating length changes in this segment during CSM. [17–19]

One approach to investigate the relationship between movement and elongation of the VA during CSM is to quantify the kinematics of the head and associated VA length change. The kinematics of the head relative to the sternum during CSM have been investigated in both asymptomatic live [20–24] and cadaveric subjects. [25, 26] Despite the use of varying CSM techniques, the current literature reports that head angular displacements during CSM are small, especially for rotation movements [25], and they do not exceed the normal physiological range of motion. [21, 23] However, in an early study, angular head displacements were shown to approach the maximal active range of motion for the upper cervical spine at the pre-manipulative position. [20]

A study by Piper et al. [26] remains the only investigation in which the kinematics of the head relative to the sternum and the associated VA length changes were measured simultaneously. However, in that study, head kinematics and VA length changes at peak CSM force occurrence were reported relative to the VA length and head/neck position in the neutral anatomical position. [26] Angular displacements and associated VA length changes during the thrust phase of CSM were not separately reported in that study and therefore remain unknown. Furthermore, it has been suggested that the force and amplitude of CSM are responsible for VA damage [15, 18, 27] and indeed, any ‘rapid jerking movement’. [28] Since the thrust phase of CSM involves a rapid increase in the applied forces and (possibly) amplitudes, it is important to quantify angular displacements of the head/neck and VA length during this phase of the procedure.

Including the Piper et al. investigation, four studies have quantified the elongation response of the VA to CSM and passive ranges of motion. [26, 29–31] In these studies, arterial length changes were reported for specific regions [26, 29] or, along the entire course of the artery [30, 31] following CSM delivered to a maximum of three vertebral levels. Collectively, it was found that from a neutral anatomical head and neck position, movements involving contralateral (opposite to the side of VA instrumentation) head rotation resulted in the largest VA length changes in the V3 segment during both CSM (range – 15 to 18%) and passive ranges of motion (0–38%). [26, 29–31] From a neutral head and neck position, VA length changes measured during CSM were typically lower than those measured during passive range of motion testing and did not approach published failure length changes (also measured as strains from a neutral head and neck position [153–162%]). [29] Further, on average, the VA must elongate about 12% prior to mechanical failure when measured from a standardized neutral anatomical position. [31]

Despite these reports, the kinematics of the head relative to the sternum and associated VA length changes during the thrust phase of CSM delivered systematically to each level of the cervical spine (C1–C7) have not been investigated. Therefore, it is unknown if VA length changes differ during the thrust phase with CSM applied to different levels of the cervical spine. Furthermore, in previous studies [26, 29–31], total length changes of VA from a neutral anatomical reference position were reported. The length changes of the VA for these situations might be thought of as the length change from the reference position to the pre-manipulative position (setup phase) plus the length change of the VA during the thrust phase of the CSM. However, it is unknown how much each phase contributes to the total VA length changes during CSM.

Therefore, the purpose of this study was to systematically quantify the angular displacements of the head relative to the sternum and the associated VA length changes during the thrust phase of two types of CSM (rotation and lateral flexion), applied bilaterally, to each level of the cervical spine (C1–C7). It was hypothesized that there would be no differences in VA length changes (whole artery or V3 segment) during CSM applied to the different vertebral levels (e.g. C1 vs. C2).



Methods

      Donor recruitment and preparation

Three male cadaveric donors were secured through the University of Calgary’s Body Donation Program (January 2016—December 2019). The study was approved by the Conjoint Health Research Ethics Board (REB16-0296) of the University of Calgary. Visual inspection revealed no substantial anatomic variations in the origin, course or appearance of the VA. Minor osteophytes were present in the cervical spine of all donors; however, this did not affect the passive ranges of motion of the neck assessed qualitatively prior to dissection. Blunt dissection of the anterior cervical region was performed by a trained anatomist (~ 10 years’ experience) to expose the VA.

All efforts were made to ensure that the minimum amount of tissue was removed to approximate, as closely as possible, the contributions of soft tissues of the neck to movement. A single VA was instrumented with 2 mm piezoelectric ultrasound crystals (Sonometrics Corporation, London, Canada). Eight crystals were inserted into the lateral aspect of the artery’s lumen along its entire length and secured to the arterial wall using three non-collinear sutures (Fig. 1). Great care was taken to maintain consistency in crystal spacing (10–30 mm) and location across all donors.

Crystals 1–8 were inserted as follows:

(1)   at the mid-point between the subclavian artery and the C6 transverse foramen;

(2–5)   at the mid-point between adjacent transverse foramen of C6 to C2;

(6, 7)   adjacent to the C2 and C1 transverse foramen respectively and;

(8)   distal to the C1 transverse foramen.

There were 2 instances when it was not possible to follow this exact pattern due to normal anatomical variations between donors. Anatomical variations included limited space between adjacent transverse foramen prevented placement of crystals and enlarged cervical nerve roots exiting the neural foramen. [32] Following crystal placement, single 3 mm stainless steel surgical bone pins (IMEX Veterinary Inc, Longview, TX, USA) were introduced into the skull and sternum. Dental cement (Bosworth Company, Skokie, IL, USA) was used to secure the pins with a curing time of at least 10 h. During this time, all exposed tissues were covered in gauze soaked in a physiological saline solution. Where possible, the duration of dissection and instrumentation (~ 16 to 24 h) was minimized and when no active work was occurring, the cadaver was stored at 4 °C to reduce tissue deterioration. Prior to data collection, prefabricated triads consisting of three non-collinear, 10 mm diameter retroreflective marker spheres were firmly affixed to each bone pin using quick-setting steel reinforced epoxy (JB Kwik Weld, Sulphur Springs, TX, USA).

      Data collection

Three clinicians (clinical experience 7–20 years) performed all CSM. For each donor, data were collected from two clinicians, thus different individuals contributed to the data. The in-situ head position was taken as the arbitrary position that the skull assumed when positioned on the gurney, and was not controlled within or between donors. This position was determined by the bony anatomy of the head and neck alone and was not controlled. The order of manipulation delivery was random and established using the randomized number generator function in Matlab (vR2019b; Mathworks, USA). Clinicians delivered a single supine, Diversified style (manual, high-velocity low-amplitude) CSM (rotation and lateral flexion) to each cervical vertebra (C1 to C7) on both sides of the neck. [33]

For all procedures, the articular column of the involved vertebra was targeted through the intact posterior tissues by the antero-lateral aspect of the proximal phalanx of the clinician’s second digit. The pre-manipulative position involved head and neck flexion, ipsilateral (same side as the clinician's contact) lateral flexion, and contralateral (opposite side to the clinician's contact) rotation. The pre-manipulative position was defined as the position of the head and neck at the instant of the rapid increase in manipulative force following the relatively steady pre-manipulative force and indicated the onset of the manipulative thrust. From the pre-manipulative position, a rapid, controlled low-amplitude thrust was applied in an intended posterior-anterior (rotation) or medial and slightly inferior (lateral flexion) direction. [33]

Figure 2

During each trial, VA length changes in a single VA were captured using a SonoSoft system (Sonometrics Corporation, London, ON, Canada; 260–557 Hz) with a spatial resolution of 16 µm. [29] Prior to, and as necessary throughout data collection, arteries were perfused with ultrasonographic gel to approximate their in-vivo shape and to promote ultrasound signal transmission. For each CSM, the force–time profile was recorded using a thin, flexible pressure pad (Pedar-X, Novel, Munich, Germany; ~ 20 cm × 10 cm × 0.2 cm, 100–200 Hz), enabling identification of the time of the pre-manipulative position (thrust onset) and peak force (end of the thrust phase) (Figure 2). A sampling rate of 100 Hz was used in the first data collection. This was increased to 200 Hz for all subsequent data collection. A sampling rate of 100 Hz is adequate to quantify high-velocity, low-amplitude SM thrusts. [34]

The pad was placed securely between the clinician’s contact and the donor’s neck. [35] Three-dimensional (3D) angular displacements of the head relative to the sternum were recorded using an eight-camera optical motion capture system (Motion Analysis, Santa Rosa, CA, USA; 120–240 Hz video, 2,400 Hz analogue). A sampling rate of 120 Hz was used in the first data collection. This was increased to 240 Hz for all subsequent data collection. All data were time synchronized using a square wave 5 V electrical pulse at the beginning of each trial. The rising edge of the synchronization pulse was identified in a Matlab script (vR2019b; Mathworks, USA) and designated as time zero across systems. Thereafter, data frames for each system were converted to time in seconds based on the respective sampling frequencies. This approach enabled data extraction across systems at common event timings. Following data collection, Computed Tomography (CT) images of the donor skull to the level of the thoracic spine were acquired (Revolution GSI, GE Healthcare, Chicago, IL, USA).

      Data analysis

VA lengths acquired with the SonoSoft system were exported to Excel (Microsoft Office 365, Redmond, WA, USA). Intersegmental elongations were summed to give: (i) overall VA length change along the entire artery and; (ii) VA length change in the V3 segment (Fig. 1). VA length change (D) was calculated as:

where L0 was the instantaneous length of the artery at the pre-manipulative position, and L1 the instantaneous length of the vessel at the time of peak force during the manipulative thrust.

Figure 3

Reflective marker positions were tracked using Cortex software (v5.02, Motion Analysis, CA, USA) and filtered using an 8 Hz, low pass, 4th order zero-lag Butterworth filter in Matlab. [36] Orthonormal coordinate systems were defined for the skull and sternum in Matlab using donor-specific 3D bone models created using manual segmentation from the CT images (Mimics, v21, Materialise NV, Belgium). The origin of the skull was located in the centre of the foramen magnum. The origin was defined using the mean coordinates of the mid-points of the lines connecting (1) the left and right inferior lateral, and (2) the anterior and posterior inferior aspects of foramen magnum (Figure 3). The medial–lateral axis was defined in the direction of the inferior lateral aspects of the foramen magnum. The superior-inferior axis was defined using the cross product of the vectors of the medial–lateral and intermediate anterior–posterior axis (i.e. inferior anterior and posterior aspects of foramen magnum). The final anterior–posterior axis was defined as the cross product of the vectors representing the medial–lateral and superior-inferior axes.

The origin of the sternum was defined as the mean coordinates of the mid-points of the lines connecting (1) the left and right lateral inferior aspects of the articular facets for the clavicles, and (2) the most superior and inferior aspects of the midline of the sternum. The medial–lateral axis was defined in the direction of the lateral aspects of the sternum. The anterior–posterior axis was defined using the cross product of the vectors of the medial–lateral and intermediate superior-inferior axis (i.e. superior and inferior aspects of the midline). The final superior-inferior axis was defined as the cross product of the vectors representing the medial–lateral and anterior–posterior axes. The coronal axis (X), was defined as positive to the left, the sagittal axis (Y), positive posteriorly, and the transverse axis (Z), positive superiorly (Figure 3). Change in head angular displacements relative to the three axes of the sternum LCS were calculated from the time of onset to the time of peak force occurrence during the CSM thrust.

      Statistical analysis

Descriptive statistics [mean ± standard deviation (SD), (range)] were used to report the angular displacement of the head relative to the sternum and the VA length changes (whole vessel and V3 segment) during CSM. Differences in VA length changes between adjacent cervical vertebra (i.e. C1 compared to C2 etc.) were evaluated using the Wilcoxson Signed Rank Testing Exact method (SPSS, version 27, IBM, USA). Statistical significance was set at p < 0.05.



Results

Table 1

Table 2

Table 3

Table 4

Table 5

One hundred and sixty-eight CSM were delivered to three male cadaveric donors (88 ± 6 years old; Table 1) in this study, with 165 being used for analysis. There were no significant differences in VA length changes (whole artery or V3 segment) during CSM applied to the different vertebral levels (e.g. C1 vs. C2) (Tables 2–4). Therefore, the descriptive statistics were calculated by pooling data from all CSM; i.e. thrusts delivered to each level of the cervical spine (C1 to C7) and on both sides of the neck for all donors and all clinicians (Table 5).

Irrespective of the type of CSM, the side or level of CSM application, angular displacements of the head and associated VA length changes during the thrust phase of CSM were small (Tables 2–5). Furthermore, visual inspection of the data revealed that there was considerable variability in the length changes measured in the whole artery and V3 segment across different donors and clinicians (Tables 2–5).



Discussion

The purpose of this study was to quantify the angular displacements of the head relative to the sternum and the associated VA length changes during the thrust phase of two types of CSM (rotation and lateral flexion), applied bilaterally, to each level of the cervical spine (C1 to C7). The primary result of this study was that irrespective of the type of CSM, the side or level of CSM application, angular displacements of the head and associated VA length changes during the thrust phase of CSM were small (Tables 2–5) compared to those occurring at peak CSM force occurrence in the only other study to measure these two parameters simultaneously. [26] Additionally, visual inspection of the data revealed that there was considerable variability in the length changes measured in the whole artery and V3 segment across different donors and clinicians (Tables 2-5).

The current results report similar amounts of flexion, lateral flexion and axial rotation during the manipulative thrust as reported previously, despite methodological differences in the CSM technique used and vertebral level contacted. [20, 22–25, 37] Additionally, there did not appear to be a relationship between the vertebra to which the thrust was applied and the change in angular displacement of the head relative to the sternum during the thrust. [21, 37] Likewise, there were no significant differences in VA length changes when CSM thrusts were applied to the different vertebral levels (Table 4).

However, as the angular displacement of the head relative to the sternum was quantified, and VA length changes were measured for the entire VA and the V3 segment, it is possible that there are differences in the segmental motion and intersegmental VA length changes between adjacent cervical vertebrae. Supporting this argument for differences in segmental vs. global kinematics, it has been reported that angular displacements of individual cervical vertebrae in sagittal plane flexion/extension of the head may be greater at intermediate head flexion/extension angles than at maximal head flexion/extension angles. [38] Additionally, VA length changes were observed in opposite directions in adjacent motion segments i.e. elongation at the C1/2 level and shortening at the C2/3 level, consistent with one previous report. [30]

Another consideration is that despite considerable variability, there was, on average, an elongation of the V3 segment – irrespective of the vertebra targeted by the CSM (Tables 2–5). This finding may be important as VA dissections occur more frequently in the V3 segment than in other areas of the VA. [17–19] However, it should be noted that even though the V3 segment usually elongated during CSM, there were instances when a shortening of the V3 segment was observed (maximum of – 9.3%) (Table 2).

This highlights possible biomechanical differences in VA response between individuals receiving CSM. Visual inspection of the data did not reveal any patterns regarding VA response between donors or practitioners, thus it is unknown exactly what causes this variability but it is possible that anatomic differences in the course of the vessel (thus reducing the length of the V3 segment) [18] and/or variable CSM thrust delivery by different practitioners [39] may be important factors. Variability in the length changes associated with CSM has been reported previously. [26, 29–31] However, there does not appear to be a qualitative difference in the variability of VA length changes between the lateral flexion and rotation CSM delivered in this study.

      Limitations

This study involved cadaveric donors where dissection artifacts were unavoidable. While every effort was made to minimize alteration of tissues, dissection artifacts may have contributed to the mechanics of CSM and head motion that may not directly generalize to the clinical setting. Specifically, there could be differences in load transfer from the practitioner to the cadaver compared to from the practitioner to a live patient, due to the removal of soft tissues which could result in increased magnitudes of head displacements during CSM delivered to cadaveric donors.

Thus, it is possible that with the removal of soft tissues, VA length changes may have been overestimated here compared to those occurring in a clinical situation. Furthermore, as the donor temperature was lower than that of a living body, it is possible that biomechanical responses (e.g., flexibility, stiffness) of the soft tissues may have been affected. However, we are unsure how it would be possible to conduct these experiments at, or close to, body temperature and do not believe that this was an important factor during data collection.

Additionally, in patients, the VA experiences not only longitudinal (measured in our study) but also pulsatile circumferential and radial strains due to blood pressure. We made no attempt to pressurize the artery (to mimic radial strains) and did not measure either circumferential or radial strains. Further, no attempt was made to differentiate length changes within the three separate layers of the vessel wall. However, as longitudinal length changes have been implicated primarily as the cause of VA injury, and the current methods likely approximate these length changes, we are confident that we closely represent longitudinal length changes occurring in-vivo during CSM. [40]

A limitation of the measurement technique is that the piezoelectric crystals measure straight-line inter-crystal distances. As such, if the VA is not straight (as we observed), the inter-crystal distance would be shorter than if the vessel was straight. However, when the VA is not straight, and is slack, then there is no strain or stress imposed on the VA and absolute length and length changes are less important to measure accurately, as ultimately, the interest is in determining when the VA is not slack anymore, becomes a straight line, and becomes strained and experiences longitudinal stress. At that point, which is the crucial part of the VA mechanics, the ultrasound crystals measure accurately the strains from which the associated stresses can be determined accurately.

Another limitation of this study is that VA length changes were measured only for the thrust phase of CSM, no standardized reference length for comparison with literature values of VA length changes occurring at the time of peak force occurrence were available. In other words, a VA length change of 3% measured in this study, could be a length change from 94–97% of the reference length (100%) from a standardized neutral anatomical head and neck configuration [26, 29–31], or it could be from 107 to 110%, or from 123 to 126%. The absence of a standardized reference configuration, thus, does not allow for statements regarding the potential damage of the VA due to over-stretching.



Conclusions

Head angular displacements and VA length changes were small during CSM thrusts. Of the four CSM procedures measured, mean VA length changes were largest during rotation procedures. This suggests that if clinicians wish to limit VA length changes during the thrust phase of CSM, consideration should be given to the type of CSM used.


Acknowledgements

Additionally, the authors would like to thank the donors and staff at The University of Calgary Body Donation Program and support staff—Mr. Andrew Sawatsky and Mr. Hoa Nguyen and Drs. Tim Leonard and Seong-won Han.


Author contributions

LG: conceptualization, methodology, data collection, data analysis, investigation, writing—original draft.

GK: data collection, data analysis, investigation, writing—review and editing.

JR: resources, data analysis, writing—review and editing.

JT: data analysis, writing—review and editing.

RC & BS: data collection.

WH: conceptualization, methodology, resources, writing—review and editing. All authors read and approved the final manuscript.


Funding

The authors would like to thank the funding sources, The Canadian Chiropractic Research Foundation and the Alberta College and Association of Chiropractors.


Ethics approval and consent to participate

The study was approved by the Conjoint Health Research Ethics Board (REB16-0296) of the University of Calgary.


Competing interests

The authors declare no competing interests.



REFERENCES:

  1. Martin, BI, Deyo, RA, Mirza, SK et al.
    Expenditures and Health Status Among Adults
    With Back and Neck Problems

    JAMA 2008 (Feb 13); 299 (6): 656–664

  2. James SL, Abate D, Abate KH, Abay SM, Abbafati C, Abbasi N, et al.
    Global, regional, and national incidence, prevalence, and years lived
    with disability for 354 diseases and injuries for 195 countries and
    territories, 1990–2017: a systematic analysis for the
    global burden of disease study 2017.
    The Lancet. 2018;392(10159):1789–1858.
    doi: 10.1016/S0140-6736(18)32279-7.

  3. Fejer R, Kyvik KO, Hartvigsen J.
    The prevalence of neck pain in the world population:
    a systematic critical review of the literature.
    Eur Spine J. 2006;15(6):834–848.
    doi: 10.1007/s00586-004-0864-4.

  4. R. Bryans, P. Decina, M. Descarreaux, et al.,
    Evidence-Based Guidelines for the Chiropractic Treatment
    of Adults With Neck Pain

    J Manipulative Physiol Ther 2014 (Jan); 37 (1): 42–63

  5. Hurwitz, EL, Carragee, EJ, van der Velde, G et al.
    Treatment of Neck Pain: Noninvasive Interventions: Results
    of the Bone and Joint Decade 2000–2010 Task Force on
    Neck Pain and Its Associated Disorders

    Spine (Phila Pa 1976). 2008 (Feb 15); 33 (4 Suppl): S123–152

  6. Bussières, AE, Stewart, G, Al Zoubi, F et al.
    The Treatment of Neck Pain-Associated Disorders and
    Whiplash-Associated Disorders:
    Clinical Practice Guideline

    J Manipulative Physiol Ther. 2016 (Oct); 39 (8): 523–564

  7. Bier JD, Scholten-Peeters WGM, Staal JB, Pool J, van Tulder MW, Beekman E, et al.
    Clinical practice guideline for physical therapy assessment
    and treatment in patients with nonspecific neck pain.
    Phys Ther. 2018;98(3):162–171.
    doi: 10.1093/ptj/pzx118.

  8. Whalen W, Farabaugh RJ, Hawk C, Minkalis AL, Lauretti W, Crivelli LS, et al.
    Best-Practice Recommendations for Chiropractic Management
    of Patients With Neck Pain

    J Manipulative Physiol Ther. 2019 (Nov); 42 (9): 635–650

  9. Bronfort G, Haas M, Evans R, Leiniger B, Triano J.
    Effectiveness of Manual Therapies: The UK Evidence Report
    Chiropractic & Osteopathy 2010 (Feb 25); 18 (1): 3

  10. Gross A, Miller J, D’Sylva J, Burnie S, Goldsmith G, Graham N et al..
    Manipulation or Mobilisation For Neck Pain:
    A Cochrane Review

    Manual Therapy 2010 (Aug); 15 (4): 315–333

  11. Puentedura EJ, March J, Anders J, Perez A, Landers MR, Wallmann HW, et al.
    Safety of cervical spine manipulation: are adverse events preventable
    and are manipulations being performed appropriately?
    A review of 134 case reports.
    J Man Manip Ther. 2012;20(2):66–74.
    doi: 10.1179/2042618611Y.0000000022.

  12. Di Fabio RP.
    Manipulation of the cervical spine: risks and benefits.
    Phys Ther. 1999;79(1):50–65.

  13. Biller J, Sacco RL, Albuquerque FC, et al.:
    Cervical Arterial Dissections and Association With Cervical
    Manipulative Therapy A Statement for Healthcare Professionals
    From the American Heart Association/ American Stroke Association

    Stroke. 2014 (Oct); 45 (10): 3155–3174

  14. Ernst E.
    Adverse effects of spinal manipulation:
    a systematic review.
    J R Soc Med. 2007;100(7):330–338.
    doi: 10.1177/014107680710000716.

  15. Frisoni GB, Anzola GP.
    Vertebrobasilar ischemia after neck motion.
    Stroke. 1991;22:1452–1460.
    doi: 10.1161/01.STR.22.11.1452.

  16. Assendelft WJ, Bouter LM, Knipschild PG.
    Complications of spinal manipulation:
    a comprehensive review of the literature.
    J Fam Pract. 1996;42(5):475–480.

  17. Haldeman S, Kohlbeck FJ, McGregor M.
    Stroke, Cerebral Artery Dissection, and
    Cervical Spine Manipulation Therapy

    J Neurology 2002 (Jul); 249 (8): 1098–1104

  18. Mann T, Refshauge KM.
    Causes of complications from cervical spine manipulation.
    Aust J Physiother. 2001;47(4):255–266.
    doi: 10.1016/S0004-9514(14)60273-7.

  19. Mitchell J.
    Vertebral artery blood flow velocity changes associated with
    cervical spine rotation: a meta-analysis of the evidence
    with implications for professional practice.
    J Man Manip Ther. 2009;17(1):46–57.
    doi: 10.1179/106698109790818160.

  20. Triano JJ, Schultz AB.
    Motions of the head and thorax during neck manipulations.
    J Manip Physiol Ther. 1994;17(9):573–583.

  21. Klein P, Broers C, Feipel V, Salvia P, Van Geyt B, Dugailly PM, et al.
    Global 3D head-trunk kinematics during cervical spine
    manipulation at different levels.
    Clin Biomech. 2003;18(9):827–831.
    doi: 10.1016/S0268-0033(03)00170-0.

  22. Ngan JMW, Chow DHK, Holmes AD.
    The kinematics and intra- and inter-therapist consistencies of
    lower cervical rotational manipulation.
    Med Eng Phys. 2005;27(5):395–401.
    doi: 10.1016/j.medengphy.2004.10.009.

  23. Williams JM, Cuesta-Vargas AI.
    An investigation into the kinematics of 2 cervical manipulation techniques.
    J Manip Physiol Ther. 2013;36(1):20–26.
    doi: 10.1016/j.jmpt.2012.10.018.

  24. Liguo Z, Minshan F, Xunlu Y, Shangquan W, Jie Y.
    Kinematics analysis of cervical rotation-traction
    manipulation measured by a motion capture system.
    Evid Based Compl Alternat Med. 2017;2017:5293916.

  25. Dugailly P-M, Beyer B, Sobczak S, Salvia P, Feipel V.
    Global and regional kinematics of the cervical spine during upper
    cervical spine manipulation: a reliability analysis of 3D motion data.
    Man Ther. 2014;19(5):472–477.
    doi: 10.1016/j.math.2014.04.017.

  26. Piper SL, Howarth SJ, Triano J, Herzog W.
    Quantifying strain in the vertebral artery with simultaneous motion
    analysis of the head and neck: a preliminary investigation.
    Clin Biomech. 2014;29(10):1099–1107.
    doi: 10.1016/j.clinbiomech.2014.10.004.

  27. Smith RA, Estridge MN.
    Neurologic complications of head and neck manipulations:
    report of two cases.
    J Am Med Assoc. 1962;182(5):528–531.
    doi: 10.1001/jama.1962.03050440020005.

  28. Haldeman S, Kohlbeck FJ, McGregor M
    Risk Factors and Precipitating Neck Movements Causing
    Vertebrobasilar Artery Dissection After Cervical
    Trauma and Spinal Manipulation

    Spine (Phila Pa 1976) 1999 (Apr 15); 24 (8): 785–794

  29. Symons, B.,Leonard, T.R.,Herzog, W.,2002.
    Internal Forces Sustained by the Vertebral Artery
    During Spinal Manipulative Therapy

    J Manipulative Physiol Ther 2002 (Oct); 25 (8): 504–510

  30. Wuest, S, Symons, B, Leonard, T, and Herzog, W.
    Preliminary Report: Biomechanics of Vertebral Artery
    Segments C1-C6 During Cervical Spinal Manipulation

    J Manipulative Physiol Ther. 2010 (May); 33 (4): 273–278

  31. Herzog, W., Leonard, T. R., Symons, B., Tang, C., & Wuest, S.
    Vertebral Artery Strains During High-speed,
    Low amplitude Cervical Spinal Manipulation

    J Electromyography and Kinesiology 2012 (Oct); 22 (5): 740–746

  32. Sugimoto T, Ochi K, Hosomi N, Mukai T, Ueno H, Takahashi T, et al.
    Ultrasonographic reference sizes of the median and ulnar nerves
    and the cervical nerve roots in healthy Japanese adults.
    Ultrasound Med Biol. 2013;39(9):1560–1570.
    doi: 10.1016/j.ultrasmedbio.2013.03.031.

  33. Esposito S, Philipson S, Downie A.
    Spinal adjustment technique:
    The Chiropractic Art. 1st ed.
    Craft Printing P/L, Australia; 2005.

  34. Gudavalli MR, DeVocht J, Tayh A, Xia T.
    Effect of sampling rates on the quantification of forces, durations,
    and rates of loading of simulated side posture high-velocity,
    low-amplitude lumbar spine manipulation.
    J Manip Physiol Ther. 2013;36(5):261–266.
    doi: 10.1016/j.jmpt.2013.05.010.

  35. Herzog W:
    The Biomechanics of Spinal Manipulation
    J Bodyw Mov Ther. 2010 (Jul); 14 (3): 280–286

  36. Schreven S, Beek PJ, Smeets JBJ.
    Optimising filtering parameters for a 3D motion analysis system.
    J Electromyogr Kinesiol. 2015;25(5):808–814.
    doi: 10.1016/j.jelekin.2015.06.004. 37. Van Geyt B, Dugailly P-M, Klein P, Lepers Y, Beyer B, Feipel V.
    Assessment of in vivo 3D kinematics of cervical spine manipulation:
    influence of practitioner experience and occurrence of cavitation noise.
    Musculoskelet Sci Pract. 2017;28:18–24.
    doi: 10.1016/j.msksp.2017.01.002.

  37. Van Mameren H, Drukker J, Sanches H, Beursgens J.
    Cervical spine motion in the sagittal plane (I) range of motion
    of actually performed movements, an X-ray cinematographic study.
    Eur J Morphol. 1990;28(1):47–68.

  38. Herzog W.
    The Biomechanics of Spinal Manipulation
    J Bodyw Mov Ther. 2010 (Jul); 14 (3): 280–286

  39. Johnson CP, How T, Scraggs M, West CR, Burns J.
    A biomechanical study of the human vertebral artery with
    implications for fatal arterial injury.
    Forensic Sci Int. 2000;109(3):169–182.
    doi: 10.1016/S0379-0738(99)00198-X.

Return to STROKE AND CHIROPRACTIC

Since 9-22-2022

                  © 1995–2024 ~ The Chiropractic Resource Organization ~ All Rights Reserved